Item Number: AT-N594

NITROGEN DIOXIDE BADGE, 10/BX

594 Nitrogen Dioxide Monitor, 10/Bx

Associated Analytical Methods: Modified OSHA 109, 182, and 200, NIOSH 6014
Item Number: AT-N594
Availability: Drop Ship From Manufacturer

Our 594 Nitrogen Dioxide Monitor allows for easy and cost-effective determination of personal exposure to nitrogen dioxide. Nitrogen dioxide is trapped on glass fiber filter impregnated with triethanolamine. The resulting nitrite ions are quantitated by colorimetry or ion chromatography.

This badge is NON-RETURNABLE

This badge does not collect nitric oxide.

This badge does collect sulfur dioxide. The sampling rate of 16.7 mL/min has been lab verified. However this chemical is not part of AT Labs accreditation yet. Other laboratories can use and analyze this badge.

 

This badge collects the following:

  • Nitrogen dioxide
  • Sulfur dioxide

More Information on the Sampling Guide.

Before sampling, ship and store at room temperature. After sampling, store and ship at room temperature.  Ship for samples to arrive at the laboratory within 28 days of sampling. 8-hour TWA sampling. Note: Reporting limit for a 15-minute STEL sample is 0.8 ppm.

Use this badge for 15-minute STEL/Ceiling limit sampling.

Also, use this badge for 24-hour Indoor Air Quality (IAQ) sampling.

Our 594 Nitrogen Dioxide Monitor allows for easy and cost-effective determination of personal exposure to nitrogen dioxide. Nitrogen dioxide is trapped on glass fiber filter impregnated with triethanolamine. The resulting nitrite ions are quantitated by colorimetry or ion chromatography.

This badge is NON-RETURNABLE

This badge does not collect nitric oxide.

This badge does collect sulfur dioxide. The sampling rate of 16.7 mL/min has been lab verified. However this chemical is not part of AT Labs accreditation yet. Other laboratories can use and analyze this badge.

 

This badge collects the following:

  • Nitrogen dioxide
  • Sulfur dioxide

More Information on the Sampling Guide.

Before sampling, ship and store at room temperature. After sampling, store and ship at room temperature.  Ship for samples to arrive at the laboratory within 28 days of sampling. 8-hour TWA sampling. Note: Reporting limit for a 15-minute STEL sample is 0.8 ppm.

Use this badge for 15-minute STEL/Ceiling limit sampling.

Also, use this badge for 24-hour Indoor Air Quality (IAQ) sampling.


Cross-reference of Assay Monitors with 3M Monitors

 Assay Monitors  3M Monitors
 AT-N555  3M-3551
 AT-N566  3M-3500
 AT-N566  3M-3520
 AT-N571  3M-3721

*The above table of cross-referenced product information is for comparison purposes only. The information about non-Zefon products was gathered from published price lists, websites and catalogs of other manufacturers and providers, which information may change from time to time. Any Trademarks listed are owned by their respective owner. No ownership is implied. Please note packaging quantities between manufacturers may vary.

 Item  Before Sampling  After Sampling
 AT-N525, AT-N543, AT-N546, AT-N566  Store and Ship at Room Temperature  Store and Ship at Room Temperature

 Return to Lab within 14 days
 AT-N549  Store and Ship at Room Temperature  Store and Ship at Room Temperature

 Return to Lab within 14 days
 AT-N555  Store and Ship at Room Temperature  Room Temperature

 Return to Lab within 14 days
 AT-N571  Ship at Room Temperature to arrive within 2 calendar days. Store under refrigerated conditions for maximum shelf life.  Room Temperature

 Return to Lab within 28 days
 AT-N574  Store and Ship at Room Temperature  Room Temperature

 Return to Lab within 14 days
 AT-N575  Store and Ship at Room Temperature  Room Temperature

 Return to Lab within 14 days. (Lot 3C20 and after)
 AT-N581  Ship at Room Temperature to arrive within 2 calendar days. Store under refrigerated conditions for maximum shelf life.  Room Temperature

 Return to Lab within 28 days
 AT-N584  Ship at Room Temperature to arrive within 2 calendar days. Store under refrigerated conditions for maximum shelf life.  Room Temperature

 Return to Lab within 14 days
 AT-N585  Ship at Room Temperature to arrive within 2 calendar days. Store under refrigerated conditions for maximum shelf life.  Room Temperature

 Return to Lab within 28 days
 AT-N586  Ship at Room Temperature to arrive within 2 calendar days. Store under refrigerated conditions for maximum shelf life.  Room Temperature

 Return to Lab within 14 days
 AT-N587  Store and Ship at Room Temperature  Room Temperature

 Return to Lab within 14 days 
 AT-N592  Ship at Room Temperature to arrive within 2 calendar days. Store under refrigerated conditions for maximum shelf life.  Room Temperature

 Return to Lab within 14 days
 AT-N593  Store and Ship at Room Temperature  Room Temperature

 Return to Lab within 28 days
 AT-N594  Store and Ship at Room Temperature  Room Temperature

 Return to Lab within 28 days
 AT-N595  Store and Ship at Room Temperature  Store and Ship under Refrigeration

 Return to Lab within 3 days
 AT-N596  Store and Ship at Room Temperature  Room Temperature

 Return to Lab within 14 days

Technical Documents

 Product  Technical Documents
 AT-N525
 AT-N543
 AT-N546
 AT-N555
 AT-N566
 AT-N571
 AT-N575
 AT-N581
 AT-N584
 AT-N585
 AT-N586
 AT-N592
 AT-N593
 AT-N594

 

Products specifications
MANUFACTURER Assay Technology
TYPE Nitrogen Dioxide
Products specifications
MANUFACTURER Assay Technology
TYPE Nitrogen Dioxide
Categories