Search
Filters
Close
Item Number: AT-N566

ORGANIC VAPOR BADGE, 10/BX

566 Organic Vapor Monitor, 10/Bx

Associated Analytical Methods: NIOSH 1500, NIOSH 1550, NIOSH 1604
Item Number: AT-N566
Manufacturer PN: N566
Availability: Drop Ship From Manufacturer

The 566 Organic Vapor Monitor is our most versatile and popular organic vapor badge. The 566 utilizes our ChemDisk II configuration with a flexible, inert charcoal wafer, making it smaller and much easier to use than other badges on the market. The 76-hole sampling grid allows for sampling rates around 8 mL/min. While the 8-hour reporting limits vary from chemical to chemical (see our Sampling Guide), most are in the 0.1 ppm range, well below most OSHA PELs and NIOSH RELs. In addition, the 566 badge has much more sampling capacity than most other badge and tube methods.

This badge is NON-RETURNABLE

Assay Technology also has two other Organic Vapor badges for more extreme environments. The 546 High Capacity Monitor is used when monitoring an environment for chemicals with high PELs (200 ppm and higher). The 525 TraceAir II Organic Vapor Monitor is used for STEL and IAQ monitoring where low reporting limits are essential and low concentrations are expected. For assistance in choosing which is best for your situation, view our guide for selecting which Organic Vapor badge you should use. Please note: The 566 monitor can NOT be used for acetic acid monitoring. See our 543 Acetic Acid Monitor.  

Industrial Hygiene Labs:

  • Sampling rates are listed in our Sampling Guide or Requested Sampling Rates page (search by CAS #). Contact us if you can’t find a rate you need.
  • Opening the ChemDisk is made much easier using the pick we specify.
  • Media is available for QC testing. Use our M products (e.g. M566).

This badge collects the following:

  • Xylenes
  • Methylene Chloride
  • Benzene
  • Toluene
  • Acetone
  • Styrene
  • Methyl Ethyl Ketone
  • Isopropyl Alcohol
  • Methyl Alcohol (STEL only)
  • Ethyl Alcohol
  • Hexane
  • Ethyl Acetate
  • Heptane
  • Ethylbenzene
  • Acetonitrile
  • Methyl Methacrylate
  • Hydrocarbons, Total

More Information on the Sampling Guide.

Store at room temperature before and after use. Refrigerated storage is OK.

It is recommended that the badge be returned to the lab within 14 days of use.

The extremely versatile 566 badge can be used in most environments.

  • STEL and Ceiling
  • TWA
  • IAQ
  • Can be used for longer periods of time

If very low reporting limits are needed and there is believed to be very little organic vapor in the air, such as an Indoor Air Quality situation, then the fast-sampling 525 TraceAir II badge may be the best option.  If concentrations of 200 ppm or higher are expected during an 8-hour monitoring, the High Capacity 546 badge may be best.  Call our customer service department for advice or review our Guide online.

The 566 Organic Vapor Monitor is our most versatile and popular organic vapor badge. The 566 utilizes our ChemDisk II configuration with a flexible, inert charcoal wafer, making it smaller and much easier to use than other badges on the market. The 76-hole sampling grid allows for sampling rates around 8 mL/min. While the 8-hour reporting limits vary from chemical to chemical (see our Sampling Guide), most are in the 0.1 ppm range, well below most OSHA PELs and NIOSH RELs. In addition, the 566 badge has much more sampling capacity than most other badge and tube methods.

This badge is NON-RETURNABLE

Assay Technology also has two other Organic Vapor badges for more extreme environments. The 546 High Capacity Monitor is used when monitoring an environment for chemicals with high PELs (200 ppm and higher). The 525 TraceAir II Organic Vapor Monitor is used for STEL and IAQ monitoring where low reporting limits are essential and low concentrations are expected. For assistance in choosing which is best for your situation, view our guide for selecting which Organic Vapor badge you should use. Please note: The 566 monitor can NOT be used for acetic acid monitoring. See our 543 Acetic Acid Monitor.  

Industrial Hygiene Labs:

  • Sampling rates are listed in our Sampling Guide or Requested Sampling Rates page (search by CAS #). Contact us if you can’t find a rate you need.
  • Opening the ChemDisk is made much easier using the pick we specify.
  • Media is available for QC testing. Use our M products (e.g. M566).

This badge collects the following:

  • Xylenes
  • Methylene Chloride
  • Benzene
  • Toluene
  • Acetone
  • Styrene
  • Methyl Ethyl Ketone
  • Isopropyl Alcohol
  • Methyl Alcohol (STEL only)
  • Ethyl Alcohol
  • Hexane
  • Ethyl Acetate
  • Heptane
  • Ethylbenzene
  • Acetonitrile
  • Methyl Methacrylate
  • Hydrocarbons, Total

More Information on the Sampling Guide.

Store at room temperature before and after use. Refrigerated storage is OK.

It is recommended that the badge be returned to the lab within 14 days of use.

The extremely versatile 566 badge can be used in most environments.

  • STEL and Ceiling
  • TWA
  • IAQ
  • Can be used for longer periods of time

If very low reporting limits are needed and there is believed to be very little organic vapor in the air, such as an Indoor Air Quality situation, then the fast-sampling 525 TraceAir II badge may be the best option.  If concentrations of 200 ppm or higher are expected during an 8-hour monitoring, the High Capacity 546 badge may be best.  Call our customer service department for advice or review our Guide online.


Cross-reference of Assay Monitors with 3M Monitors

 Assay Monitors  3M Monitors
 AT-N555  3M-3551
 AT-N566  3M-3500
 AT-N566  3M-3520
 AT-N571  3M-3721

*The above table of cross-referenced product information is for comparison purposes only. The information about non-Zefon products was gathered from published price lists, websites and catalogs of other manufacturers and providers, which information may change from time to time. Any Trademarks listed are owned by their respective owner. No ownership is implied. Please note packaging quantities between manufacturers may vary.

 Item  Before Sampling  After Sampling
 AT-N525, AT-N543, AT-N546, AT-N566  Store and Ship at Room Temperature  Store and Ship at Room Temperature

 Return to Lab within 14 days
 AT-N549  Store and Ship at Room Temperature  Store and Ship at Room Temperature

 Return to Lab within 14 days
 AT-N555  Store and Ship at Room Temperature  Room Temperature

 Return to Lab within 14 days
 AT-N571  Ship at Room Temperature to arrive within 2 calendar days. Store under refrigerated conditions for maximum shelf life.  Room Temperature

 Return to Lab within 28 days
 AT-N574  Store and Ship at Room Temperature  Room Temperature

 Return to Lab within 14 days
 AT-N575  Store and Ship at Room Temperature  Room Temperature

 Return to Lab within 14 days. (Lot 3C20 and after)
 AT-N581  Ship at Room Temperature to arrive within 2 calendar days. Store under refrigerated conditions for maximum shelf life.  Room Temperature

 Return to Lab within 28 days
 AT-N584  Ship at Room Temperature to arrive within 2 calendar days. Store under refrigerated conditions for maximum shelf life.  Room Temperature

 Return to Lab within 14 days
 AT-N585  Ship at Room Temperature to arrive within 2 calendar days. Store under refrigerated conditions for maximum shelf life.  Room Temperature

 Return to Lab within 28 days
 AT-N586  Ship at Room Temperature to arrive within 2 calendar days. Store under refrigerated conditions for maximum shelf life.  Room Temperature

 Return to Lab within 14 days
 AT-N587  Store and Ship at Room Temperature  Room Temperature

 Return to Lab within 14 days 
 AT-N592  Ship at Room Temperature to arrive within 2 calendar days. Store under refrigerated conditions for maximum shelf life.  Room Temperature

 Return to Lab within 14 days
 AT-N593  Store and Ship at Room Temperature  Room Temperature

 Return to Lab within 28 days
 AT-N594  Store and Ship at Room Temperature  Room Temperature

 Return to Lab within 28 days
 AT-N595  Store and Ship at Room Temperature  Store and Ship under Refrigeration

 Return to Lab within 3 days
 AT-N596  Store and Ship at Room Temperature  Room Temperature

 Return to Lab within 14 days

Technical Documents

 Product  Technical Documents
 AT-N525
 AT-N543
 AT-N546
 AT-N555
 AT-N566
 AT-N571
 AT-N575
 AT-N581
 AT-N584
 AT-N585
 AT-N586
 AT-N592
 AT-N593
 AT-N594

 

Products specifications
ANALYSIS Not Included
MANUFACTURER Assay Technology
TYPE Organic Vapor
Products specifications
ANALYSIS Not Included
MANUFACTURER Assay Technology
TYPE Organic Vapor
Customers who bought this item also bought
Categories