Search
Filters
Close
Item Number: NXT-50811000-310N

VERIFIT IRRITANT SMOKE GENERATOR, 10/PK

VeriFit Irritant Smoke Generators for Respirator Fit Testing, 10/pk
Item Number: NXT-50811000-310N
Manufacturer PN: 50811000-310N
Manufacturer: Nextteq
Availability: In Stock

The VeriFit® Irritant Smoke Generator revolutionizes respirator fit testing. Its patented design integrates all traditional irritant smoke test components into one convenient device. Plastic construction eliminates danger from broken glass. Small, attached bellows provide the optimum amount of smoke yet minimize overexposure.

Unlike other test methods, there is no need for nebulizers, pumps, mixing jars, batteries, test masks, probes, or hoods. There are no parts to calibrate, warm up, sterilize, or clean.

Irritant smoke is the only OSHA-accepted qualitative fit testing method that does not rely on the test subject’s subjective response. Other types of qualitative fit tests, such as banana oil (Isoamyl acetate), saccharin, or Bitrex, may cause false negative results

Each VeriFit Irritant Smoke Generator is a complete, safe, ready-to-use, OSHA-compliant fit testing kit.

NOTE: For information about which respirators may be fit tested using irritant smoke, please refer to the following document: Fact Sheet - Respirators to Fit Test

Contents: 10 smoke generators, manual, & storage box

Download the Sensitivity Check Protocol PDF

Download the VeriFit Manual

Download the VeriFit SDS

Download the VeriFit Brochure

The VeriFit® Irritant Smoke Generator revolutionizes respirator fit testing. Its patented design integrates all traditional irritant smoke test components into one convenient device. Plastic construction eliminates danger from broken glass. Small, attached bellows provide the optimum amount of smoke yet minimize overexposure.

Unlike other test methods, there is no need for nebulizers, pumps, mixing jars, batteries, test masks, probes, or hoods. There are no parts to calibrate, warm up, sterilize, or clean.

Irritant smoke is the only OSHA-accepted qualitative fit testing method that does not rely on the test subject’s subjective response. Other types of qualitative fit tests, such as banana oil (Isoamyl acetate), saccharin, or Bitrex, may cause false negative results

Each VeriFit Irritant Smoke Generator is a complete, safe, ready-to-use, OSHA-compliant fit testing kit.

NOTE: For information about which respirators may be fit tested using irritant smoke, please refer to the following document: Fact Sheet - Respirators to Fit Test

Contents: 10 smoke generators, manual, & storage box

Download the Sensitivity Check Protocol PDF

Download the VeriFit Manual

Download the VeriFit SDS

Download the VeriFit Brochure

Products specifications
TYPE SMOKE
Products specifications
TYPE SMOKE
Customers who bought this item also bought
Categories